An LG dryer showing a TE1 error code usually has a faulty thermistor, the temperature sensor that tells the main control board how hot the dryer is running. The first fix is to unplug the dryer for about five minutes and restart it, which is the reset LG’s support site lists for thermistor codes and the step AppliancePartsPros gives for LG dryer TE1. If the code returns, the cause is almost always the thermistor, a loose connection in its wiring, or, less often, the control board itself.
Most people assume a TE1 error means the dryer is finished and a replacement is coming. That’s usually wrong. The thermistor is a small part, and the troubleshooting steps below run from a free reset to a simple resistance test with a multimeter. I’ll also cover the vent checks that can trigger temperature codes and exactly when to call a pro for help.
What Does TE1 Mean on an LG Dryer?
The TE1 error code means the dryer’s electronics have detected a problem with the thermistor circuit. LG’s support list of every LG dryer error code says tE1 indicates a problem with the dryer’s thermistor, and that the usual fix is a reset. A thermistor is a temperature sensor whose electrical resistance shifts with heat, and that shift is how the board gets its temperature reading and holds the drying temperature steady.
When that reading goes missing or lands out of range, the dryer can’t manage its heating cycle safely, so it stops and puts the error code on the display. Appliance Tech Info, a service-code reference, describes the fault as a thermistor resistance that’s open or shorted. An open circuit means the signal path is broken, while a short circuit means current is taking a path it shouldn’t. The board can’t trust either one, so the dryer shuts off the cycle, and PartSelect says it needs a reset, a repair, or both before it runs again.
Why Does an LG Dryer Throw a TE1 Code?
AppliancePartsPros and Appliance Tech Info both list the same three causes for an LG dryer TE1 error. The first is a faulty thermistor. The second is a loose connection or damaged wiring harness between the thermistor and the board. The third is a defective main control board that can’t read the signal correctly.
My own ranking puts the thermistor first, the wiring second and the board a distant third. That order is my judgment, not a manufacturer statistic. Most people miss this entirely: the board is the priciest item on the list, which is exactly why it should be the last thing you suspect.
Airflow is the fourth suspect. PartSelect says a TE1 code on an LG dryer is most often tied to the thermistor or to an airflow restriction from lint buildup. A failed thermistor is also a different fault from a blown thermal fuse or a worn heating element, so I’d only check those if your service manual points you there.
How to Fix TE1 on an LG Dryer, Step by Step

These troubleshooting steps run from free to cheap, and on an electric dryer this is a manageable DIY repair. You’ll need a screwdriver, a multimeter, and your dryer’s model number so you can pull up the right service manual. Unplug the dryer before you touch anything inside it, and read the safety section of your LG owner’s manual before opening the cabinet.
- Power cycle the dryer. Unplug the dryer, wait about five minutes, plug it back in and start a new cycle. LG’s support page calls this a factory reset, and AppliancePartsPros lists it first. If the TE1 error doesn’t return, you’re done.
- Check the dryer vent. Pull the dryer forward and make sure the duct isn’t crushed or kinked behind it. Empty the lint filter, then clean the vent from the dryer to the outside hood so hot air can leave the drum.
- Find the thermistor. Its location varies by model, but AppliancePartsPros says it’s usually near the exhaust vent. Use your model number to find the exact spot in the service manual.
- Inspect the wiring connector. With the dryer unplugged, look for a loose connection, a pinched wire or scorched insulation at the thermistor and along the harness. Reseat the connector.
- Run the resistance test. Disconnect the thermistor leads, set the multimeter to ohms, touch one probe to each lead and compare the reading with the resistance values in your service manual. A reading that’s open, shorted or far off the manual’s values means the thermistor has failed.
- Replace the thermistor. Order the exact replacement part by model number, install it, reconnect the harness and run a short cycle to clear the error code. If TE1 still shows with a good new thermistor and sound wiring, the main control board is the next suspect.
This usually goes wrong when someone replaces the thermistor without checking the connector, and the same loose connection brings TE1 right back.
Can a Clogged Vent Trigger TE1?
It can contribute, according to PartSelect, which ties TE1 to restricted airflow from lint buildup as well as to the thermistor. LG’s own error code list also has separate codes for a clogged exhaust duct: d75, d80, d90 and d95. If one of those shows on your display instead of TE1, start with the vent.
Appliance Care Guide lists symptoms that travel with a temperature fault. The dryer stops mid-cycle, there’s a dryer not heating problem, or damp clothes come out after a long drying time. Those overlap with a blocked vent and overheating, which is why the vent check comes before any part gets ordered. From experience, the smarter move is to rule out the free cause first.
Most Guides Skip This About TE1 and the Other Thermistor Codes
LG’s error code list treats tE1 and tE3 together as thermistor problems and describes tE2 as a thermistor error that normally shows up during cold conditions. So the three codes are related, but they aren’t interchangeable. If your dryer sits in an unheated garage and shows tE2, the cold may be the trigger.
Here’s the part almost nobody mentions: published sources disagree on which physical thermistor each code points to. One repair site says tE1 is the inlet thermistor, while Appliance Tech Info describes the tE1 thermistor as the blower thermistor. Because the sources conflict, don’t order a part based on the code number alone. Match it to your model number and service manual, and ask LG parts support if the manual is unclear.
When Should You Call a Technician?
Call an appliance technician if TE1 returns after the reset, the vent is clear, and the thermistor and wiring both test fine. That pattern points at the main control board, and LG’s support page says a code that persists after the reset may need repair service. The same goes for scorched wiring, and for any job near the gas line if you own a gas dryer.
I wouldn’t keep running the dryer in the meantime. The MyPros error code reference says running a dryer with an active tE1 error isn’t recommended and suggests leaving it out of service until the thermistor circuit has been inspected. Hunker’s LG error code overview says dryers purchased in 2011 or later support Smart Diagnosis, which lets LG’s service line read the error by phone, so keep your model number handy. If your dryer keeps showing TE1 after all six steps, book the visit. Repair cost varies by region and by part, so ask for a quote before you confirm the service call.
LG Dryer TE1 FAQs
What does TE1 mean on an LG dryer?
TE1 means the dryer has detected a thermistor, or temperature sensor, problem, according to LG’s support error code list. Reset the dryer first, then check the wiring and the thermistor if the code returns.
Will unplugging the dryer clear the TE1 error code?
It can, if the error was a one-time glitch, and LG lists a reset as the usual first fix. If the thermistor or its wiring is actually failing, the code will come back on the next cycle.
Can a dirty dryer vent cause TE1?
It can contribute, since PartSelect ties TE1 to lint-related airflow restriction. LG also uses separate codes, d75, d80, d90 and d95, to flag a clogged exhaust duct.
Is TE1 the same as tE2 or tE3?
No. LG groups all three under thermistor problems, but its support page says tE2 normally appears during cold conditions, while tE1 and tE3 are listed together.
Your Next Step

Start with the free fix: unplug the dryer for five minutes, restart it and clean the vent. If TE1 comes back, pull your model number, find the thermistor in the service manual and run the resistance test before you buy anything. That one test tells you whether you’re facing a simple thermistor replacement or a control board that needs a professional.